WILO TWU 3-0303-HS-ECP BOREHOLE PUMP
Submersible pump for vertical or horizontal installation.Hydraulics
Multistage submersible pump with radial impellers with sectional construction. Integrated non-return valve. All parts in contact with the fluid are made of corrosion-free materials.
Motor
Corrosion-free asynchronous motor for connection to the frequency converter supplied (HS-E…) or for direct connection to the mains power supply (HS-I…). Rewindable oil-filled motor with self-lubricating bearings, designed for high speeds up to 8400 rpm.
Frequency converter
External frequency converter or frequency converter integrated within the motor, for operation of the pump at speeds up to 8400 rpm, including the following functions:
• Soft starter
• Undervoltage, overvoltage and short-circuit protection
• Thermal overload protection of the motor and the frequency converter
The version "HS-E…“ with external frequency converter offers the following additional equipment features:
• Control function "CP“: Constant pressure
• Avoidance of frequent switching (cycling) by leakage monitoring
• Dry-running protection with automatic reset
• Change of direction of rotation
• Setting for max. flow and target pressure
• Pressure is shown on the display
• Settings, operating statuses and error messages are shown by LEDs or on the display.
The frequency converter always must be installed outside the fluid where it will be protected against overflows!
Control function "CP“: Constant pressure
Operation with the frequency converter means the rotation speed of the unit is adapted to the current water requirements automatically. As a result, the submersible pump always delivers a constant pressure.
Cooling
The motor is cooled by the fluid. The motor must always be operated in submerged state. The limit values for the max. fluid temperature and the minimum flow rate must not be exceeded.
In cases of vertical installation, a cooling jacket must be provided depending on the diameter of the bore. In cases of horizontal installation, a cooling jacket must always be provided .
The external frequency converter is also cooled by the fluid. For this the frequency converter must be installed directly in the piping outside the fluid (overflow-proof).