The following outlines the standard specification: • Minimum recommended working pressure 1 bar. • Maximum working pressure 15 bar. • All cylinder connections are 22mm compression. • Units tested to 15 bar. • Minimum water supply 1.5 bar, 20 litres/min. • Primary coil circuit must be pumped. • Gravity coils available by special order. • Stainless steel stat pocket guaranteed against corrosion. Homeflow has the following advantages: • 25 Year vessel guarantee. • Cylinder components guaranteed for 2 years. • Available in a range of styles sizes 90 to 600 litres. • A range of horizontal cased units. • Coil in coil high efficiency coil - high recovery rates. • External expansion for reliability and flexible sitting. • Full Kiwa Approval. |