Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw buy online at trade prices  | blog | feedback | view cart | contact us | faq | home
April Fools Day
Shopping cart
You have no items
in your trolley.
SubTotal : £0.00

Contact MyTub for plumbing supplies 0844 556 1818


Plumbing Trade prices delivered to your door

Upto 60% off RRP
Tuesday 1, April 2025
login / register
 
  Departments
Bathroom & Kitchen Bathroom & Kitchen Supplies
Heating System Supplies Heating System Supplies
Parts and Spares Parts and Spares Supplies
Drainage Above & Below Ground Drainage System Supplies
Air Conditioning & Refrigeration Supplies Air Conditioning & Refrigeration Supplies
Packaged Industrial Units and ASHPs Packaged Industrial Units and ASHPs
Carrier Industrial Products Carrier Industrial Products
Daikin Altherma Daikin Altherma
Daikin Chillers Daikin Chillers
Fujitsu Waterstage Fujitsu Waterstage
Toshiba Estia Toshiba Estia

  Manufactures
Manufactures Manufactures list

  Collections
collections Design collections
Home > > > > > >

Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw


Daikin Altherma -  Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw

26% 26 percent off rrp

Department: Daikin Altherma
  Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw
    Inverter technology
Weather dependent Control
Disinfection function
Split refrigerant system glycol not needed Designed for sever winters, guaranteed operation down to -25°C Includes high efficiency pump, expansion vessel, PRV, strainer, isolation valves, back-up heater Back-lit plain text controller with full heating and hot water programmer, and room thermostat function Schedule timer
Night setback
Space heating and domestic hot water heating with boost functions
Low noise levels from outdoor units (sound power as low as 61 dBa at 1m from unit)
MCS Accredited (eligible for RHI where designed at max 50°C flow temperature)
Listed on Product Characteristics Database (SAP-Q)
Compatible with underfloor heating and Solar
End User 3 year parts and labour warranty
Multiple set point control
Flow temperatures are up to 55°C (models 011-016)
ERLQ models 004-008: Heating -20°C to +25°C, Hot water -20°C to +35°C
ERLQ models 011-016, Heating -20°C to +35°C, Hot water -20°C to +35°C
Capacity/COP (A7/W35) ERLQ004, 4.4kW/5.04
Capacity/COP (A7/W35) ERLQ006, 6.0kW/4.74
Capacity/COP (A7/W35) ERLQ008, 7.4kW/4.45
Capacity/COP (A7/W35) ERLQ011, 11.2kW/4.60
Capacity/COP (A7/W35) ERLQ014, 14.5kW/4.30
Capacity/COP (A7/W35) ERLQ016, 16.0kW/4.25
  Daikin Altherma Low Temperature (LT) Split system is a tried and tested concept first launched in 2006 with over 200,000 installed across Europe. The latest model heat pump is the perfect choice for all new build and many refurbishment projects. The system comprises an outdoor unit which extracts energy from the outside air, connected by refrigerant pipework which delivers this energy to an indoor unit (or hydrobox) which can be located up to 50m away (ERLQ011-016)/ 30m (ERLQ004-008). Offers greatest running cost savings for off-gas properties. Must be installed by a competent person holding F-gas certification, G3 (unvented cylinders) and Part P certification and who have also attended the following training courses at Daikin: SE15 (Heating Design and Application) PLUS SE11 (LT Installation and Commissioning).
Manufacture: Daikin
Notes: Brand : Daikin
CoEfficient of Performance (%) : 3ph
Colour : Cream
Decibels (db) : 51
Defrost Cycle : Y
Dim 1 (mm) : 1345
Dim 2 (mm) : 900
Dim 3 (mm) : 320
Engine Size (kVA) : 114
KW : 11kw
Length (mm) : -
Litre : -
Model Number : ERLQ011CW1
Range : Altherma
Voltage : 400v
Warranty : 3 Year
Phase : 3ph
Cooling kW Sensible : -
Cooling kW Total : -
Heating Capacity (kw) : -
Daikin
Code#:
ERLQ011CW1
MyTub Code#: 738408
 
rrp£6330.80
save£1675.80
price£4655.00

inc vat£5586.00

email for overseas delivery charges

Stock Check Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw check stock here..
   
 

Related Daikin Altherma Products
Daikin Third Party Tank Connection Kit
Related item Daikin Third Party Tank Connection Kit
rrp£382.53
our price£281.28
Daikin Altherma Erlq008cv3 Low Temperature 1 Phase 8kw
Related item Daikin Altherma Erlq008cv3 Low Temperature 1 Phase 8kw
rrp£3723.00
our price£2737.50
Daikin Ekhwsu200b3v3 2001 Un Vented Cylinder 1 Phase 3kw
Related item Daikin Ekhwsu200b3v3 2001 Un Vented Cylinder 1 Phase 3kw
rrp£1579.61
our price£1161.48
Daikin G3 Kit For White Cylinders Ekhwsu
Related item Daikin G3 Kit For White Cylinders Ekhwsu
rrp£749.07
our price£550.79
Daikin Ekrp1aht Daikin Demand Control Ekrp1aht
Related item Daikin Ekrp1aht Daikin Demand Control Ekrp1aht
rrp£223.99
our price£164.70
Daikin Ersq011av1 Out Door Unit Heating 1 Phase 11kw
Related item Daikin Ersq011av1 Out Door Unit Heating 1 Phase 11kw
rrp£5967.00
our price£4387.50
Daikin Ekhwsu300b3v3 3001 Un Vented Cylinder 1 Phase 3kw
Related item Daikin Ekhwsu300b3v3 3001 Un Vented Cylinder 1 Phase 3kw
rrp£1809.43
our price£1330.46
Daikin Hybrid Controller Ekrucbl2
Related item Daikin Hybrid Controller Ekrucbl2
rrp£183.28
our price£134.76

Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw Delivered to your door

Shopping cart
Your Shopping Cart is Empty

Contract Pricing and Quantity Discounts available

  Recently viewed  
Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw daikin altherma erlq011cw1 3 phase low temperature heat pump 11kw
£4655.00

Feedback
Dear Jeanette, Thank you very much in turn for your help and promt correspondence - excellent customer service! (Please show this to your line manager) Best wishes,
...Haydn Stanley
excellence service and a prompt delivery, would use again
...paul redford
Unfortunately my parcel was delivered to the wrong address in Portslade. The gentleman who signed the delivery note made out it was for him although the address label was clearly for me in Southwick. The delivery driver was contacted via My Hub and was able to collect the parcel and bring it to me the next day. The parcel had been opened and there was no paperwork or fitting instructions in the box. It appears the man in Portslade did not know where he had put them. I do have to stress that when putting addresses into a sat nav the post code should be used as often road names occur in neighbouring towns.
...Frances Burt
Great service. The toilet seat arrived very quickly and provided great customer service.
...Lian agnew
Got the product I wanted at the best price I could find. Slight mix up on delivery date and pedestal came later but sorted out OK and very good customer service. Would give 4 out of 5 given mix up but 5 out of 5 if it were not for that. Would definitly reccommend and go back if I need anything in future.
...Mr P Mooney
Delivered on time, no problems using Mytub.
...Dot Yang
Good service, would recommend and use again!
...mike chilvers
Very good service, was kept informed by email on delivery date. Very satisfied with the sink. Would use again. Thank you
...wayne botley
Exemplary service. Originally placed order on ebay but was let down greatly. Your companys handling of my order was first rate and your communications excellent. I was updated regularly regarding the delivery status leaving me free to carry on with other things. THANK YOU.
...Patricia Lines
Everything perfect! Quality and price the best and delivery speed amazing. On my favorites now! David
...David Pedder

Why choose MyTub Limited for daikin altherma erlq011cw1 3 phase low temperature heat pump 11kw ERLQ011CW1?

  • Fast deliveries
  • Nationwide UK distribution delivery network
  • Local pickup if required
  • Professional Human Service
  • Pre sales tech advice
  • Second to none after sales service
  • This daikin altherma erlq011cw1 3 phase low temperature heat pump 11kw ERLQ011CW1 is a genuine branded product
  • Worldwide export if required
  • Read what the experts, our customers have to say above.

Price Match Guaranteed

MyTub ltd Plumbing Supplies  
    Verified Credit Score by CheckRate
  VAT relief for disabled people MyTub is a member of the British Chambers of Commerce  
Major credit cards accepted
Verified by VISA  
MasterCard SecureCode
MyTub Ltd
61 Victoria Terrace
Whitley Bay
Tyne & Wear
NE26 2QN
Company No. 06352542
VAT number: 917634607
Telephone 0844 5561818 calls are charged at 7p per minute PLUS your telephone network will charge you which can be significant.
Copyright 2007 - 2025 © MyTub Ltd
Daikin Climate
Daikin Altherma Erlq011cw1 3 Phase Low Temperature Heat Pump 11kw